Components

Litronic FMS RMH12 pipe sensor

Physical principleCoaxial field in a cylinder condenser
Frequency20 MHz
Measurement locationPipe diameter 12 mm
Process connectionErmeto cutting ring screw connection 12 mm, M18x1.5
Measuring range0 – 100 % water content, measuring window adjustable
Capacity resolution250 aF
Update cycle33.33 ms
Maximum attainable measuring accuracy+/- 10 ppm water content 1.)
Measurement value transferdigital: RS-485, streaming
Max. number of sensors on the bus4
Maximum bus length1200 m
Power supply12-24 V, 0.5 VA
Temperature measurement measuring range5 – 90 °C
Operating ambient temperature5 – 60 °C
Storage temperature-40 – 60 °C 2.)
Protection classIP65
Max. pressure6 bar
Volume flow5 - 1200 l/h
Connection line length/typeUNITRONIC® ROBUST C 7x0.14 shielded/6 m
Housing materialV4A (1.4305)
Dimensions: Ø/Length54/219 (230) mm
Weight without cableapprox. 2.1 kg

Sales contact person

Liebherr-Mischtechnik GmbH

Service contact person

Liebherr-Mischtechnik GmbH