Components

Litronic FMS P78 planar sensor

Sensor/electronics evaluation

Physical principleCapacity determination in the high frequency stray field
Frequency20 MHz
Measurement locationMeasurement location: Outside silo via baffle plate, on belt with sliding shoe carriage, pipes, screw conveyors, tank, etc.
Measuring range0-100 % moisture content
Capacity resolution3 fF
Update cycle32.64 ms
Sampling rate mean value counter16 – 25 106
Maximum attainable measuring accuracy+/- 0.05 % moisture content 1.)
Measurement value transferdigital: RS-485, multiprocessor log
Max. number of sensors on the bus16
Maximum bus length1200 m
Power supply8 - 30V, 0.4 VA
Temperature measurement measuring range-10 – 90 °C
Measuring accuracy temperature measurement+/- 0.5 °C
Operating ambient temperature5 – 72 °C
Working temperature - electronics-20 – 80 °C
Storage temperature-25 – 80 °C
Protection classIP68
Connection cable typeUNITRONIC®ROBUST C 7x0.14 shielded
Connection cable length6 m
Wearing protection:Zirconium oxide (ZrO2Al2O3)
Housing/flange materialV4A (1.4404)
Dimensions: Ø / Height / Height with cable connection78 mm / 42,5 mm / 62,5 mm
Weight without cable0.500 kg
Weight clamping flange0.300 kg

Sales contact person

Liebherr-Mischtechnik GmbH

Service contact person

Liebherr-Mischtechnik GmbH