Components

Litronic-FMS P30-S planar sensor

Physical principleCapacity determination in the high frequency stray field
Frequency20 MHz
Measurement locationConstrained installation conditions, pipes, screw conveyors, fluidised bed dryer nerve
Measuring range0 – 100 % moisture content (measuring window adjustable)
Capacity resolution3 fF
Update cycle32.64 ms
Sampling rate mean value counter16 – 25 106
Maximum attainable measuring accuracy+/- 0.05 % moisture content 1.)
Data interfaceRS-485 EIA-485
Maximum bus length1200 m
Measurement value transferhalf-duplex
Bus arbitrationMaster/Slave
Data format:9600bit/s 9 data, 1 stop
Logproprietary multiprocessor log
Max. number of sensors on the bus16
Measured value streamingsimplex
Bus arbitrationautomatic
Data format:19200 bit/s, 8 data, 1 Stop, no Parity
Outputbinary 2 temperatures and raw value
Output cycle33 Hz
Max. number of sensors on the bus4
Power supply8 - 30V, 0.4 VA
Temperature measurement measuring range-10 – 90 °C
Measuring accuracy temperature measurement+/- 0.5 °C
Operating ambient temperature5 – 72 °C
Working temperature - electronics-20 – 80 °C
Storage temperature-25 – 80 °C
Protection classIP68
Connection cable typeUNITRONIC®ROBUST C 7x0.14 shielded
Connection cable length6 m
Wearing protectionPEEK
Housing/flange materialV4A (1.4404)
Dimensions: Ø/Length30/94 mm
Weight without cable0.500 kg

Sales contact person

Liebherr-Mischtechnik GmbH

Service contact person

Liebherr-Mischtechnik GmbH