Liebherr-Mischtechnik GmbH
88427 Bad Schussenried
Germany
+49 7583 9498-07
Small, fine, excellent: The Liebherr P30-S sensor in conjunction with the Liebherr FMS moisture measuring installation has become indispensable for many industrial processes.
The “Little One” expanded our product portfolio in 2008.
Measurement by the Liebherr sensor system is based on the physical principle of capacitance determination in the high-frequency stray field.
In addition to their high precision and robustness, the measuring devices from Bad Schussenried are characterised by their reproducibility.
Once the sensor has been calibrated, further measuring points can be set up or devices renewed on this basis at any time without great effort. The plant thus always remains reliable, regardless of its previous term and age.
| Physical principle | Capacity determination in the high frequency stray field |
| Frequency | 20 MHz |
| Measurement location | Constrained installation conditions, pipes, screw conveyors, fluidised bed dryer nerve |
| Measuring range | 0 – 100 % moisture content (measuring window adjustable) |
| Capacity resolution | 3 fF |
| Update cycle | 32.64 ms |
| Sampling rate mean value counter | 16 – 25 106 |
| Maximum attainable measuring accuracy | +/- 0.05 % moisture content 1.) |
| Data interface | RS-485 EIA-485 |
| Maximum bus length | 1200 m |
| Measurement value transfer | half-duplex |
| Bus arbitration | Master/Slave |
| Data format: | 9600bit/s 9 data, 1 stop |
| Log | proprietary multiprocessor log |
| Max. number of sensors on the bus | 16 |
| Measured value streaming | simplex |
| Bus arbitration | automatic |
| Data format: | 19200 bit/s, 8 data, 1 Stop, no Parity |
| Output | binary 2 temperatures and raw value |
| Output cycle | 33 Hz |
| Max. number of sensors on the bus | 4 |
| Power supply | 8 - 30V, 0.4 VA |
| Temperature measurement measuring range | -10 – 90 °C |
| Measuring accuracy temperature measurement | +/- 0.5 °C |
| Operating ambient temperature | 5 – 72 °C |
| Working temperature - electronics | -20 – 80 °C |
| Storage temperature | -25 – 80 °C |
| Protection class | IP68 |
| Connection cable type | UNITRONIC®ROBUST C 7x0.14 shielded |
| Connection cable length | 6 m |
| Wearing protection | PEEK |
| Housing/flange material | V4A (1.4404) |
| Dimensions: Ø/Length | 30/94 mm |
| Weight without cable | 0.500 kg |
1) representative of the batch or the time window in the Contiprocess, in conjunction with the associated Litronic-FMS II evaluation device, material-dependent, with ideal flow behaviour and with proper calibration
Characteristics
• Pure capacitive measuring method
• Sensor exchange without recalibration
• Sensitivity adjustable in 3 steps
• Integrated microprocessor with mean value calculator
• Material flow detection
• Temperature compensation
• Limit value evaluation
• Direct digital measurement value determination
• Stainless steel housing

Liebherr-Mischtechnik GmbH
+49 7583 9498-07

Liebherr-Mischtechnik GmbH
+49 7583 9498-00